Atmospheric Single-Arm Robot Safety
User’s Manual Material Safety Information
Brooks Automation
Revision 1
2-35
Section 7 Physical Data
Boiling Point ºC: NA
Specific Gravity: NA
Vapor Pressure: NA
Vapor Density: NA
Appearance and Odor: White, slight odor grease
Solubility in water: Insoluble
Melting Point ºC: NA
Section 8 Fire and Explosion Hazards
Flash Point
(COC) ºC
243 for base oil
Flammable Limit % vol in air LEL: NA
UEL: NA
Distinguishing Media
Use water fog, dry chemical, or CO
2
. Do not use direct stream of water. Product will float and can
be re-ignited on surface water.
Special Fire Fighting Procedures and Precautions
Do not enter confined fire space without proper protective equipment including a NIOSH
approved self-contained breathing apparatus. Cool fire-exposed container, surrounding equip-
ment, and structures with water.
Section 9 Reactivity
Stability: Stable.
Hazardous polymerization: Will not occur.
Conditions and Materials to Avoid: Strong Oxidizers.
Hazardous Decomposition Product
No
x
, So
x
, Co
x
, and other unidentified oxygenates can be formed during combustion.
Section 10 Employee Protection
Respiratory Protection
A NIOSH approved respiratory protection equipment should be used when vapor or mist concen-
tration exceed applicable standards.
Protective Clothing
Use oil resistant gloves and other clothing to minimize skin contact.
Section 11 Environmental Protection
Spill or Leak Procedure
Scoop up excess grease. Clean area with appropriate cleaner.
Waste Disposal
Dispose of in an appropriate disposal facility in compliance with appropriate regulations.
Section 12 Special Precautions
Store in a cool, dry place with adequate ventilation. Keep away from open flames and high temper-
ature. Minimize skin contact. Wash with soap and water before eating, drinking, smoking or using
toilet facilities.
Launder contaminated clothing before using. Discard leather goods if they cannot be decontami-
nated. Wash before eating or smoking. Observe good personal hygiene.
IDENTITY: LG 2 Grease
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com