EasyManua.ls Logo

Brother HL-2170W - Page 26

Brother HL-2170W
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-11
Confidential
6) No paper fed manual feed slot
No paper in manual feeding
7) Drum error
Dirt on drum unit
User Check
Load the paper
Step Cause Remedy
1
Harness connection failure of
registration front sensor PCB
ASSY
Check the harness connection of the
registration front sensor PCB ASSY.
2
Registration front sensor PCB
failure
Check the registration front sensor
performance following the procedure in
"Factory Inspection Mode" (Chapter 5).
If any problem occurs, replace the
registration front sensor PCB ASSY.
3 Toner LED PCB failure Replace the toner LED PCB ASSY.
4 Main PCB failure Replace the main PCB ASSY.
User Check
Clean the corona wire in the drum unit.
Replace the drum unit with a new one, and reset the drum counter.
Step Cause Remedy
1
Dirt or dust on drum unit
electrodes
Clean the electrodes on the drum unit and
the machine body (Refer to Fig. 1-2).
2
High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB.
3 Main PCB ASSY failure Replace the main PCB ASSY failure.

Table of Contents