1-12
Confidential
Electrodes location of the drum unit
Fig. 1-2
Electrodes location of the machine
Fig. 1-3
<How to clean the electrodes>
Turn off the power switch. Unplug the machine from the AC power outlet, and leave the machine
for a few minutes. Then, wipe the electrodes above carefully with a dry lint-free cloth. Be careful
not to change the shapes of the electrodes.
Side surface of
Drum unit
Charged electrode
Grid
Cleaner
Transfer roller
Exposure drum
Develop roller
Side surface of
Frame L ASSY inside
Grid
Cleaner
Transfer roller
Exposure drum
Develop roller
Charged electrode