6.3.9. Accessories
First touch SETUP, then touch ACCESSORIES to set up the parameters for the
accessories installed with the system.
A12192
6.3.9.1. Filter
NOTE: The daily duct assessment will occur even if static pressure monitoring is
disabled. This is done to ensure that the system will continue to provide proper
airflow for all installed equipment, since duct system changes may occur at any
time, such as opened or closed registers.
With this option, the installer has the option of selecting pressure monitoring, the
type of filter installed, and the time interval for cleaning. After the selections are
made, touch SAVE.
S Pressure Monitoring (not available or effective with air cleaners that do not
use filter media, such as Electric Air Cleaners): Enable or Disable
d Default = Enable
S Clean Interval: Selectable from 1 to 18 months
d Default = 3 months
S Filter Type: Air Filter, Electric Air Cleaner or Air Purifier
d Filter type is selected during installation; otherwise default = air filter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant Evolution Connex Control and is the answer not in the manual?

Bryant Evolution Connex Control Specifications

General IconGeneral
BrandBryant
ModelEvolution Connex Control
CategoryThermostat
LanguageEnglish

Related product manuals