Communication Test
SMART MATRIX WINDINGFEEDER - 19 -
Communication Test
This function allows you to check:
- The efficiency level of communications between SMART MATRIX and all the WINDINGFEEDER devices
connected.
- The correct communication with the individual devices.
Communication Efficiency
Enter the SETUP menu.
Select TEST COM.
Select LINE EFF (global communication efficiency) or
SINGLE (communication efficiency with the individual
WINDINGFEEDER devices).
Number of devices on which communication errors
occurred (DEV IN ERROR) and total number of
transmission repeated as result of detected errors (TOTAL
RETRY). A maximum of 5 transmission retries are
repeated for each device.
Global efficiency index.
Number of the selected device (1)
Status of communication between SMART MATRIX and
selected WINDINGFEEDER device (either COMM OK or
COMM ERROR).
SETUP
→
TEST COM