Operation
- 3-6 - ULTRAFEEDER
Advanced Programming of ULTRAFEEDER Devices
With the ADVANCED programming environment, each ULTRAFEEDER can be
programmed with specific control parameters which depend on the type of yarn under
processing, and on the type of application.
• MAIN TENSION Control Tension
•
ERROR TENSION Tolerance beyond which an Error is generated
•
TIME ALARM Time for which the tension may stay out of tolerance
•
INC-DEC TENSION ∆ Tension for INC/DEC graduation
•
EXIT TENSION Device Tension with machine stationary
•
RELAX YARN It corresponds to the number of revolutions carried out at
constant speed during the yarn relax stage
•
RELAX SPEED Yarn feeding speed during the RELAX YARN stage
In addition, you can program particular functions and/or service parameters that affect the
device operating mode:
•
APPLICATION Device operating mode, pre-defined according to the
application. The following pre-defined applications are
available:
SOCKS, REVERSE SOCKS, MEDICAL SOCKS,
PANTYHOSE
, SEAMLESS, KNIT, REVERSE KNIT, FLAT KNIT,
SMALL LOOM
, SEWING, RASCHEL.
•
YARN TYPE Possibility of presetting the device for management of
elastic yarns.
•
OFFSET Possibility of reading/setting the OFFSET value.
•
ACCESS CODE Possibility of setting a protection password to prevent
undesired access to the device programmable functions.
•
U-FEEDER CODE Possibility of visualizing and/or directly setting the device
identification code.
•
LANGUAGE Possibility of choosing the language used to show the
message on the device display.
•
SIGNAL POLARITY Possibility of choosing the polarity of INC-DEC and STOP
signals (either NO or NC).
• OPERATING MODE Device operating mode (MASTER 1, MASTER 2, SLAVE 1,
SLAVE 2)
• MOTOR ROTATION
Possibility of setting the motor rotation direction
Setting of these parameters is already done by BTSR during manufacturing (default
values), however it can be easily changed by the textile machine operator, to meet specific
requirements, using the advanced programming features.
ULTRAFEEDER devices offer 4 advanced programming levels: P1, P2, P3 and P4,
clearly indicated in the messages area of LCD during the programming sequences.
Within the P1 level the following parameters can be programmed:
MAIN TENSION
ERROR TENSION
TIME ALARM
INC-DEC TENSION
Within the P2 level the following parameters can be programmed:
EXIT TENSION
RELAX YARN
RELAX SPEED