5 | Installation
12 | 40 Instruction Manual MINK MV 0500-0600 B_EN_en
5.2.2 Discharge Connection
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
● Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurized air source.
Connection size(s):
– R2
Depending on the specific configuration ordered, other connection dimensions may apply.
Unless the aspirated air is discharged to the environment right at the machine:
● Make sure that the discharge line either slopes away from the machine or provide a liquid sep-
arator or a siphon with a drain cock, so that no liquids can flow back into the machine.
5.3 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
● Only use an oil type which has previously been approved and recommended by Busch.
For oil type and oil capacity see Technical Data [➔35] and Oil [➔36].
The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak
and the machine requires repair.