Technical Data | 13
Instruction Manual MINK MV 0500-0600 B_EN_en 35 | 40
13 Technical Data
MV 0500 B MV 0600 B
Nominal pumping speed (60Hz) m³/h 470 600
Ultimate pressure hPa
(mbar)
abs.
see nameplate (NP)
Nominal motor rating (50Hz / 60Hz) kW 11.0 / 12.6 15.0 / 17.3
Nominal motor speed (20Hz … 60Hz) min
-1
1200 … 3600
Noise level (ENISO2151) at 400 hPa
(mbar) abs. suction pressure (60Hz)
dB(A) 76 77
Ambient temperature range °C 0 … 40*
Gas inlet temperature range °C 0 … 40*
Oil capacity l 1.2
Weight approx. kg 495 550
Ambient pressure: Atmospheric pressure
Installation altitude: 100% load capacity (no derating) up to 1000 m; Derating 1% / 100 m at 1000…
3000 m
Permitted stationary vibration: sinusoidal
3 Hz < f < 8.72 Hz: 10 mm
8.72 Hz < f < 200 Hz: 3g
3M7 acc. IEC 60721-3-3
Supply network: TN- and TT-network (cannot be used with corner grounded networks)
Immunity: EN 61800-3, 1st and 2nd environment
Emissions: EN 61800-3, category C2 as standard
* In case of higher or lower temperatures, please consult your Busch representative.