Troubleshooting | 12
Instruction Manual MINK MV 0500-0600 B_EN_en 33 | 40
12 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
Prior to any action requiring touching the machine, let the machine cool down first.
VRE
CPL
IS
Description
IS Inlet screen CPL Coupling
VRE Vacuum relief valve
Problem Possible Cause Remedy
The machine does not start. The variable speed drive (VSD)
is not supplied with the correct
voltage.
Check the power supply.
The motor or the variable
speed drive (VSD) is defective.
Replace the motor or the
variable speed drive (VSD).
The coupling (CPL) is defective. Replace the coupling (CPL).