2 | Product Description
6 | 40 Instruction Manual MINK MV 0500-0600 B_EN_en
2.1 Operating Principle
The machine works on the claw principle.
The MINK is fully air-cooled thanks to an integrated fan in the drive unit.
In order to avoid solids from entering, the machine is equipped with an inlet screen (IS).
In order to avoid reverse rotation after switching off, the machine is equipped with a non-return
valve (NRV).
2.2 Intended Use
WARNING
In case of foreseeable misuse outside the intended use of the machine.
Risk of injuries!
Risk of damages to the machine!
Risk of damages to the environment!
● Make sure to follow all instructions described in this manual.
The machine is intended for the suction of air and other dry, non-aggressive, non-toxic and non-ex-
plosive gases.
Conveying of other media leads to an increased thermal and/or mechanical load on the machine
and is permissible only after a consultation with Busch.
The machine is intended for the placement in a non-potentially explosive environment.
The machine is designed for indoor installation, in case of outdoor installation, ask your Busch rep-
resentative in order to take specific precautions.
The machine is not capable of maintaining ultimate pressure.
● The minimum allowed ultimate pressure is to be read from the nameplate of the machine.
● By means of process control and/or vacuum relief valves it must be made sure that the mini-
mum allowed ultimate pressure will not be underrun.
The machine is suitable for continuous operation.
Note: The non-return valve (NRV) shouldn't be used as a non-return or shut off valve for the System.
The non-return valve is only to protect the pump.
If the machine needs to be maintained after shutdown:
● Provide an additional manual or automatic operated non-return valve in the suction line.
Permitted environmental conditions, see Technical Data [➔35].