6 | Commissioning
30 / 68 0870211676_RA0760A_PLUS_-0004_IM_en
– Gas Ballast Valve Control [►37],
– Warm-up / Cool-down Modes [►38],
– Optional Inlet Valve Control [►40],
– Optional Vacuum Booster Control [►42].
Do not hesitate to contact Busch to get any further information about the configuration
of your machine.
• Click on the “Help” icon in the bottom bar to get the contact information of your
Busch representative, see Bottom Bar [►11].
6.3 Start Up
CAUTION
During operation the surface of the suction and exhaust connections may reach temper-
atures of more than 70°C.
Risk of burns!
• Avoid contact with these surfaces during and directly after operation.
CAUTION
Remove covers during operation.
Risk of burns!
• If a cover is removed when the machine is operating, avoid contact with surfaces in-
side the acoustic cabinet.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
• Make sure that ear protection is being used.
To start the machine:
• Press and hold the start/stop button (SSB) for at least 3 seconds.
• Monitor the operating values (Monitoring [►44]) and make sure that they always
comply with the operating conditions, see Technical Data [►66].
As soon as a warning/alarm signal occurred:
• Investigate the cause of the signal, see Dysfunction [►51].
NOTE
Activated oil level signal.
The machine is generally shipped without oil, therefore an alarm signal occurs during
the first start-up.
• As soon as the machine has been filled with oil, acknowledge the alarm signal by fol-
lowing the Warning/Alarm Acknowledgment Procedure [►52].