7 | In Operation
36 / 68 0870211676_RA0760A_PLUS_-0004_IM_en
7.3 Ecomode
The Ecomode stops the machine when the inlet pressure has reached the preset "eco-
mode pressure" within a defined time delay and will restart once the inlet pressure ex-
ceeds the "restart pressure".
This mode is only available for “Role 2” users, see Role and User [►12].
To active and set the Ecomode:
• Go to “OPERATIONS” > “MODE”.
• Access to the second screen.
• Press on Ecomode switch button (password required).
HOME
PARAMETERS
OPERATIONS
MODE
MAINTENANCE
SYSTEM
WEEK PLANNER
Ecomode
On
NEXTPREVIOUS
10 s
Time delay
Restart pressure
100 mbar20 mbar
Ecomode pressure
• Press a value to change it.
Parameter Default value Adjustment range
Ecomode pressure 20 mbar 5 … 400 mbar
Restart pressure 100 mbar 5 … 1000 mbar
Time delay 10 s 1 … 999 s
NOTE
The control unit of the vacuum pump may send a signal to pilot an isolation valve (see
Optional Inlet Valve Control [►40]) or to control a vacuum booster (see Optional Va-
cuum Booster Control [►42]).