Maintenance | 8
0870211676_RA0760A_PLUS_-0004_IM_en 59 / 68
O-ring
1
3
¼
3x
2
12x
1x flat gasket
part no.: 0480 000 131
6 mm hex key
Max. admissible torque: 21 Nm
8.5 Machine Cleaning
Clean the cooling air inlet and outlet (CAI/CAO) with pressurised air, especially when
the machine is in a dusty environment.
Remove covers if necessary.
Wear protective glasses
and a mask