In Operation | 7
0870211676_RA0760A_PLUS_-0004_IM_en 45 / 68
7.8.2 Operating Data
This display “HOME” > “MONITORING” displays operating values, it is divided into
three different screens.
Screen 1
>
HOME
MAIN
OPERATIONS
MONITORING
MAINTENANCE
SYSTEM
ALARM
Gas-ballast valve
Open
Exhaust pressure
960 mbar
Instant absorbed power Mean absorbed power
11.5 kW 10.2 kW
Running hours since last maintenance
452 h 5462 h
Running hours total
NEXT
Gas-ballast valve:
Indicates the state of the gas ballast valve “Open” or “Closed”, see Gas Ballast Valve
Control [37].
Exhaust pressure:
Indicates the counter pressure value at the exhaust of the machine according to the se-
lected unit.
To change the unit, see System Settings [13].
Instant absorbed power:
Indicates the absorbed power (in kW) in real time.
Mean absorbed power:
Indicates the average of the absorbed power (in kW) since the last reset.
Running hours since last maintenance:
Indicates the number of operating hours of the machine since the last maintenance.
Running hours total:
Indicates the total number of operating hours since the first machine commissioning.