27
Manual SOFTENER A27-A6X code P0011144 - Rev 3 - 09/02/2017
English
SETTING
At its ! rst start-up, the device displays after a few seconds the message SERV, ! rst step of the set-
ting, which uses 5 keys:
Key Name Function
çM
Left / Menu
• Activates the menu with a long press (5 seconds)
• Ongoing setting cancellation without record
ê
Down
• Down move within a list of choices
• Decrease / change of a parameter
é
Up
• Up move within a list of choices
• Increase / change of a parameter
è
Right • Move from left to right digits (example: hours to minutes)
OK
Enter
• Enter into a menu
• Setting validation
• A long press (5 seconds) triggers a manual regeneration. During
this process, a brief press forces the trigger of the next step.
The following steps are necessary and su" cient to set the softener.
You just need to know the hardness of the raw water (concentration in lime scale), measured before
or known from the public water distribution network.
First press 3 seconds on the key M, until the message LANG appears on the display.
Step n°
Message
displayed
Purpose How to do
1
LANG
_ :_
Change language if necessary
Default value is French
OK to change
çM to cancel
FR
_ :_
Language selection
êé to select
OK to con! rm
çM to cancel
2
HOUR
00:00
Time setting : hours
êé to change
è to go to minutes
OK to con! rm
çM to cancel
MIN
15:00
Time setting: minutes
êé to change
è to go back to hours
OK to con! rm
çM to cancel
3
VOLUME
16 L
Specify the resin volume within the
softener, in liters.
êé to select
OK to con! rm
çM to cancel