7
Technical manuel CARTE ÉLECTRONIQUE A6X ADOUCISSEURS DOMESTIQUES - Rev 3 - 24/10/2016
English
12
CONSU
71
Adjust the water consumption per full rege-
neration.
Only for devices with the salt level follow-up
by smartphone app.
êé to change
OK to confi rm
çM
to go to the next step without con rming
13
SALT
2000
Adjust the salt consumption per full rege-
neration.
Only for devices with the salt level follow-up
by smartphone app.
êé to change
OK to confi rm
çM
to go to the next step without con rming
14
VOL OK
0856
Volume of softened water in liters since last
regeneration (read only info). Here: 856 liters.
çM to go to the next step
15
PEAKFL
1068
Peak fl ow in 1 h in liters/hour re-corded
since the last regeneration (only info).
Here: 1068 liters per hour.
çM to go to the next step
16
N REGE
48
Number of regenerations done since the
commissioning. May be reset.
êé to change
OK to confi rm
çM
to go to the next step without con rming
17
CHLOR
Off
Enable / disable the chlorination func-
tion. Choose ON/OFF
êé to change
OK to confi rm
çM
to go to the next step without con rming
18
ALARM
Off
Salt lack alarm enabled / disabled
Choose ON / OFF
Inactive if «CHLOR» is OFF
êé to change
OK to confi rm
çM
to go to the next step without con rming
19
SAFE L
250
Safe level value = remaining capacity
in liters below which a regeneration is
triggered.
êé to change
OK to confi rm
çM
to go to the next step without con rming
20
REGE T
02:00
Time of regeneration start.
Setting of hour
êé to change
è to go to minutes
OK to confi rm
çM
to go to the next step without con rming
M REGE
02:00
Time of regeneration start.
Setting of minutes
êé to change
è to go to hours
OK to confi rm
çM
to go to the next step without con rming
21
PRESS
4
Correction of water network pressure. To
be set from 2 to 6 bar only with propor-
tional regeneration.
êé to change
OK to confi rm
çM
to go to the next step without con rming
22
FUL RG
10
Frequency of full regenerations (to prevent
from loss of capacity occurring with time),
for softeners with pro-portional regeneration
function, to be set between 0 and 20. Here:
one full regeneration every 10 regenerations.
«O» means no full regeneration.
êé to change
OK to confi rm
çM
to go to the next step without con rming
23
STEPS
Setting of duration of each regeneration
step.
OK to change
çM
to go to the next step without con rming
BACKW
1
Backwash step
(in minutes from 0 to 99)
êé to change
OK to confi rm
çM
to go to the next step without con rming
ASPI
49
Aspiration and slow rinse step
(in minutes from 0 to 99)
êé to change
OK to confi rm
çM
to go to the next step without con rming
FAST
1
Fast rinse step
(in minutes from 0 to 99)
êé to change
OK to confi rm
çM
to go to the next step without con rming