6
Technical manuel CARTE ÉLECTRONIQUE A6X ADOUCISSEURS DOMESTIQUES - Rev 3 - 24/10/2016
English
SETTING
Push the M key during 3 seconds until display of the message LANG..
Display Purpose Action
1
LANG
Change the language
OK to change
çM to go to the next step
FR
Choose the language
(FR - CZ - DE - EN - ES - HU - IT - NL - PL - RU)
êé to change
OK to confi rm
çM
to go to the next step without con rming
2
HOUR
00:00
Time setting: hours
è to go to minutes
êé to change
OK to confi rm
çM
to go to the next step without con rming
MIN
15:00
Time setting: minutes
è to go back to hours
êé to change
OK to confi rm
çM
to go to the next step without con rming
3
VOLUME
16 L
Resin volume in liters
(05 - 10 - 16 - 20 - 22 - 28)
êé to change
OK to confi rm
çM
to go to the next step without con rming
4
HARDN
°F
Hardness unit choice:
(°F ou °d)
êé to change
OK to confi rm
çM
to go to the next step without con rming
IN
30 °F
Enter the inlet hardness
êé to change
OK to confi rm
çM
to go to the next step without con rming
OUT
5 °F
Enter the outlet hardness
êé to change
OK to confi rm
çM
to go to the next step without con rming
5
REGE ?
Trigger a regeneration ?
REFILL = Tank refi lling (if prop. regeneration)
BRINE = brine préparation (if prop. rege.)
REGE 1 = backwash
REGE 2 = aspiration + slow rinse
REGE 3 = fast rinse
OK to trigger a regeneration
OK to go through the steps
çM
to go to the next step without con rming
6
CHECK / SALT
On
Salt lack alarm enabled / disabled
Choose ON / OFF
êé to change
OK to confi rm
çM
to go to the next step without con rming
7
STD-BY
On
Program step allowing to block all
regenerations. Choose ON / OFF
êé to change
OK to confi rm
çM
to go to the next step without con rming
8
SERIES
0005
PCB version (electronic)
çM to go to the next step
9
PASSW ?
23
Enter the password 23 to enter the
advanced setting and push OK.
êé to change
OK to confi rm
çM to return to «RUNNIN»
10
PROP R
On
Enables /disables the proportional rege-
neration. Choose ON / OFF
êé to change
OK to confi rm
çM
to go to the next step without con rming
11
CAPA
2880
Modify the softening capacity of the device
(in °f.m3), which has been automatically set
once the resin volume was selected.
êé to change
OK to confi rm
çM
to go to the next step without con rming