22
EN
Checklterandushingwaterpipetomakesure
they are properly installed.
If no sewage connection is available, a collecting
basin(approx.10litres)mustbeprovided.
Pullcoverplate(8)downandcheckwhetherthe
safety stop valve (7) is open (if necessary set
groovetoverticalpositionusingscrewdriver).The
stop valve remains open at all times. Slide cover
plate back upwards.
Slowly open the stop valves before and after the
lter.Deaeratethepipeworkatthenextbleedpoint
afterthelter.
Checkthesealsoftheinstallationandthelter.
Thelterisnowreadytouse.
A backwash should be carried out if the water
pressure drops as a result of increasing levels of
dirtinthelterelement,andinanycaseatleast
every 2 months.
Asa reminder thenext backwashcan beset on
thedatering(5).
We recommend carrying out a backwash once a
month,toavoidimpuritiessettlingontheltercloth
(ormorefrequentlyforhigherlevelsofdirt).
If no sewage connection is available, a collecting
basin(approx.10litres)mustbeprovided.
►
►
1.Turncrank(3).
2.Turnrotatingknob(2)approx.4-5timescounter-
clockwise.
3. Immediately turn in opposite direction until it
stops. The process can be repeated for high
levels of dirt.
3
2
5
8
7