33
Error message Cause Remedy
Structural
err.
Error in the le list of the
data medium, data access is
uncertain.
Format data medium.
System Error
e.g. FPGA defective, invalid
setup, voltage error
Switch the printer off and then
on. Please note error details
shown on the display.
If error recurs call service.
Unknown card
Data medium not formatted. Format data medium.
Type of data medium not
supported.
Use different type of data
medium.
USB error
e.g. Too much current, no
reaction, unknown device
Do not use the USB device.
Write error
Hardware error Repeat the write process,
reformat card.
Write
protected
Data medium write protection
is activated.
Deactivate the write protection.
Table 5 Error Messages and Fault Correction
8 Fault Correction

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAB EOS and is the answer not in the manual?

CAB EOS Specifications

General IconGeneral
Power Supply100-240V AC, 50/60 Hz
Print MethodThermal transfer
Print WidthUp to 105.6 mm (depending on model)
InterfacesUSB, Serial, Ethernet
DisplayLCD
Supported BarcodesCode 39, Code 128, UPC-A, UPC-E, EAN-8, EAN-13, Interleaved 2 of 5, Data Matrix, QR Code
Supported Operating SystemsWindows
Resolution203 dpi
Media Width4.33" (110 mm)