Fig. 85 - Plate removal Fig. 86 - Cleaning
The fume exhaust system cleaning frequency depends on stove use and its installation. We recommend con-
tacting an authorised service centre for the end-of-season cleaning and maintenance operations because the
centre will perform an overall check of the parts, as well as the above-mentioned operations.
6.5 LOWER COMPARTMENT CLEANING
Once the combustion chamber cleaning is finished, we recommend cleaning the G grid on the stove back (see Fig. 87) and the V
fans to remove any dust or dirt, in order to guarantee high performance (see Fig. 88).
Every year, clean the room fan to remove ash or dust causing unbalance of the blades and greater noise.
Fig. 87 - Back grid Fig. 88 - Fans
LEGEND Fig. 87 - Fig. 88
G Grid
V Fans
6.6 FUME PIPES ANNUAL CLEANING
Clean once a week from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney
flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This
operation must be executed at least once a year.