KRISS
3
- TECNA
3
- EVO
3
- ELISE
3
- SHELL
3
- CRISTAL
3
- GLASS - VERVE AT - PRETTY AT - TITANIA AT - VENERE AT - BREEZE AT
3.3 TECHNICAL FEATURES
Fig. 3 - Inclined roof
LEGEND Fig. 3
1 Height over the ridge of the roof = 0,5 mt
2 Roof inclination ≥ 10°
3 90°
4 Measured distance at 90° from the roof surface = 1,3 mt
The chimney flue must be sealed from fumes.
It must have a vertical run without narrowing. It must be realized with fume and condensation resistant materials with ther-
mal insulation and able to last against usual mechanical stresses.
It must be insulated to avoid condensation and to reduce fume cooling effects.
The stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials. Check the distan-
ce with the chimney manufacturer.
The chimney entrance must be placed in the same room where the appliance is installed or otherwise in the adjacent room
and it must be provided with a solid and condensation collection chamber under the entrance, accessible through the sealed
metal gate.
Auxiliary exhaust fans cannot be installed neither along the chimney nor on the chimney pot.
The inner section of the chimney flue can be round (the best one) or square and the jointed sides must have a minimum radius
of 20 mm.
The section dimension must be:
minimun Ø100 mm
recommended max Ø180 mm
Made the efficiency of the chimney flue overhauled by an expert stove-repairer and if necessary cover the chimney flue with
materials in compliance with current regulations.
The flue system must be placed on the roof.
The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an example of label: