Luna Features
34 ©2022 CAE 905K560252 v1.2
CAELuna
and Live configuration features, the AdvancedLive and Complete configurations includes features to
enhance the fidelity of the simulator.
See the Appendix A - Recommended Clinical Supplies section of this user guide for information
associated with the Respiratory System features of the simulator.
Neurologic System
Luna is equipped with a number of features specifically targeted to support training for neurological
care. The infant fontanel and pupil dilation stages can be used to simulate neurological conditions.
Fontanel: A palpable anterior fontanel displays bulging, neutral and sunken conditions upon manual
filling. Using a pneumatic syringe assembly, the conditions can be manually adjusted.
Eyes: The pupils can be adjusted independently to three levels of dilation: pinpoint, normal, blown.
Manual rotation of the eyes allow you to easily simulate any combination of balanced or anisocoric
dilation.
Skin tone colored patches are provided to insert over the pupil and underneath the head skin to
simulate closed eyes.
For more information, see the Using Luna section of this user guide.
Genitourinary System
The manikin is provided with both male and female genitalia. The genitourinary system is designed
for excretion of urine upon catheterization. For more information on changing the genitalia, see the
Using Luna section of this user guide.
AdvancedRespiratory System Features
The Advanced configuration manikin breathes spontaneously with a self-regulated rate and tidal
volume sufficient to maintain a target arterial carbon dioxide partial pressure, typically 40 mmHg,
which can be adjusted by the instructor. The respiratory system is capable of simulating crisis
events.
The Advanced configuration manikin’s upper chest rises and falls synchronously with the
inflationary state of the underlying lungs. This movement is synchronized with inspiration and
expiration of spontaneous and manual ventilation of the lungs and combinations thereof.
In the Advanced configuration, the respiratory response to administered medications is automatic
and dose dependent with Maestro Modeled physiology.
The physiological mathematical models continuously calculate the patient’s arterial and venous
blood gases and pH. This data can be displayed on the Instructor Workstation.
The Luna Advanced configuration manikin features circumoral cyanosis.
Laryngospasms