Distrib. Uniformity
Distribution uniformity indicates how evenly water is applied to the surrounding area from the sprinkler
head. It can be determined using a catch-can test. The distribution uniformity affects the run time and
soak-in time. For example, the lower the distribution uniformity, the less efficient the sprinkler
performs, therefore increasing run time to ensure adequate coverage. To adjust this value, highlight the
field and press +/- to increase or decrease the value.
Manually Testing Stations
The Test Stations feature provides the ability to test a station or acquire an expected flow rate for a
station. When a station is being tested, it will ignore On-At-A-Time and flow checking rules.
To learn how to test a station, see
Testing Stations
.
Station History Report
The Station History report provides a detailed breakdown of each programmed irrigation including:
The time the station turned on for its first cycle
The number of cycles run
The total time, in minutes, the station ran
The number of gallons irrigated
The flow rate measured while the station was running
To view the Station History Report (Figure 29):
1. From Main Menu, navigate to Reports and select Station History. Station History report
displays.
2. Press the Station Up and Station Down keys to view different stations.
Figure 29: Station History Screen

Table of Contents

Other manuals for Calsense CS3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Calsense CS3000 and is the answer not in the manual?

Calsense CS3000 Specifications

General IconGeneral
BrandCalsense
ModelCS3000
CategoryController
LanguageEnglish

Related product manuals