CS3000 User’s Guide
Calsense 41
Distrib. Uniformity
Distribution uniformity indicates how evenly water is applied to the surrounding area from the sprinkler
head. It can be determined using a catch-can test. The distribution uniformity affects the run time and
soak-in time. For example, the lower the distribution uniformity, the less efficient the sprinkler
performs, therefore increasing run time to ensure adequate coverage. To adjust this value, highlight the
field and press +/- to increase or decrease the value.
Manually Testing Stations
The Test Stations feature provides the ability to test a station or acquire an expected flow rate for a
station. When a station is being tested, it will ignore On-At-A-Time and flow checking rules.
To learn how to test a station, see
Testing Stations
.
Station History Report
The Station History report provides a detailed breakdown of each programmed irrigation including:
• The time the station turned on for its first cycle
• The number of cycles run
• The total time, in minutes, the station ran
• The number of gallons irrigated
• The flow rate measured while the station was running
To view the Station History Report (Figure 29):
1. From Main Menu, navigate to Reports and select Station History. Station History report
displays.
2. Press the Station Up and Station Down keys to view different stations.
Figure 29: Station History Screen