F5 Safety test
After every opening or closing command, the board will check whether the photocells are working properly.
The safety test is always active for wireless devices.
This function only appears if the photocells have been enabled.
OFF (default) / 1=CX / 2=CY / 4=CX+CY
F6 Maintained action
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3P and closing
button on contact 2-7. All other control devices, even radio-based ones, are excluded.
OFF (default) / ON
F7 Command [2-7]
From the control device connected to 2-7 it performs the step-step (open-close-invert) or sequential (open-
stop-close-stop) command.
0 = Step-step (default) / 1 = Sequential
F9
Obstruction detection
with motor stopped
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety devices, that is,
photocells or sensitive safety-edges detect an obstruction.
OFF (default) / ON
F10
Gate state warning
output
It signals the gate status. The signal device is connected to contact 10-5.
0 = Lit when gate is open or moving (default) / 1 = when opening it fl ashes intermittently every half-
second, when closing it fl ashes intermittently every second, stays lit when gate is open, is o when
gate is closed.
F11 Encoder
Managing slow-downs, obstruction detections and sensitivity.
OFF / ON (default)
F14 Sensor type
Setting the type of accessory for controlling the operator.
0 = command with transponder sensor or magnetic card reader / 1 = command with keypad selector
(default)
F19 Automatic Closing Time
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between
1 and 180 seconds. The automatic closing does not work if any of the safety devices trigger when an
obstruction is detected, or after a total stop, or during a power outage.
OFF (default) / 1 = 1 second /... / 180 = 180 seconds
F20
Automatic closing time
after partial opening
The wait before the automatic closing starts after a partial opening command for a time of between 1 s
and 180 s. The automatic closing does not work if any of the safety devices trigger when an obstruction is
detected, or after a total stop, or during a power outage.
OFF / 1 = 1 second /... / 10 = 10 seconds (default) /... / 180 = 180 seconds
F21 Pre-fl ashing time
Adjusting the pre-fl ashing time for the fl ashing light connected to E1-W, before each maneuver. The fl ashing
time is adjustable from one to ten seconds.
OFF (
default) / 1 = 1 second /... / 10 = 10 seconds
F25 Courtesy light time
Additional (courtesy) light, stays lit for the necessary time while the gate is opening and closing.
It can be set to between 60 and 180 seconds.
60 = 60 seconds (default)/... / 180 = 180 seconds
F30 Slow-down speed
Setting the gearmotor speed during the slow-down stages.
OFF (default) / ON
This function only appears if the Encoder function is activated.
F34 Travel sensitivity
Adjusting obstruction detection sensitivity during gate-leaf travel.
10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
This function only appears if the Encoder function is activated.
F35 Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10 = maximum sensitivity / … / 100 = minimum sensitivity (default)
This function only appears if the Encoder function is activated.
F36
Adjusting the partial
opening
Adjustment as a percentage of total travel, during gate opening.
10 = 10% of the gate-leaf travel / … / 80 = 80% of the gate travel (default)
This function only appears if the Encoder function is activated.
F37
Opening slow-down
point
Percentage adjustment of the total door travel, of the opening slow-down starting point.
5 = 5% of the gate run / … / 25 = 25% of the gate-leaf travel (default) / … / 45 = 45% of the gate travel
This function only appears if the Encoder function is activated.
F38
Closing slow-down
point
Percentage adjustment of the total door travel, from the closing slow-down starting point.
5 = 5% of the gate travel / … / 25 = 25% of the gate-leaf travel (default) / … / 45 = 45% of the gate travel
This function only appears if the Encoder function is activated.