<Safety d.Test>
Disabled
Safety d.Test
< Disabled >
Safety d.Test
< CX >
Safety d.Test
< CY >
Safety d.Test
< CZ >
Safety d.Test
< CX+CY >
Safety d.Test
< CX+CZ >
Safety d.Test
< CX+CY+CZ >
Obstacle Det.
< Disabled >
<Obstacle Det.>
Disabled
Obstacle Det.
< Turn on >
Obstacle detected: when motor is stopped (gate closed or after a total stop command) it prevents any movement if safety devices,
such as photocells, detect any obstacles.
Safety test: allows the card to check the efficiency of any safety devices (i.e. photocells) after every opening or closing command.
Preflashing
< Disabled >
< Preflashing >
Disabled
Pre-flashing: after an opening or closing command, the flashing light, connected to 10-E, starts flashing before the gate begins its run
(to set the time, see “Pre-flashing timing” from the Adjust Timings menu
< LAN
ew seconds, to help release the
electrolock (to set the time, see “Ram timing” in the Adjust Timings menu).
Ram hit funct.
< Disabled >
<Ram hit funct.>
Disabled
< LAN