7.18 Gate run calibration
1) From the Encoder
menu, select “Adjust
gate run”. Press ENTER
to confirm.
2) Select “confirm
(yes) and press ENTER
to confirm.
3) the gate leaf of the
first motor will perform
a closing run until fully
closed.....
4) …then, the
gate leaf of the
second motor will
perform the same
manoeuvre
5) …then, the gate
leaf of the second
motor, will perform and
opening run until fully
open…
6) ...after which,
the gate leaf of
the first motor will
perform the same
manoeuvre
7) When the procedure is
finished, the display will show
“Set Encoder ok” for a few
seconds.
N.B. before calibrating the gate run, check that the manoeuvring area is free of any obstacles and check the proper direction of rotation of the
gearmotors. (para. 7.11)
7.19 Error messages
-“encoder ERROR”: check proper connections or functionality of the device and possibly even the motor’s torque
- “Error!1 or Error!2 during adjustment: check proper connection of encoder and that device is working properly.
-“safety d. test ERROR”: malfunctioning of safety devices, check proper functioning of connections and functionalities;
-“end stop ERROR”: check proper connections on end point connections or functionality of devices;
-“cycle time ERROR”: check the working time settings, the set time may be insufficient to complete the duty cycle.
- Safety STOP, C1, C3, C4”: check proper functioning of connections and functionalities of devices.
Set Encoder
Þß
Set Encoder
confirm? (yes)
<>
Set Encoder
confirm? (no)
Þß
Set Encoder
Close 1
Set Encoder
Close 2
Set Encoder
Open 2
Set Encoder
Open 1
Set Encoder
OK