EasyManua.ls Logo

CAME ZLJ24 - Deceleration and Sensitivity Settings; Deceleration Speed Adjustment; Delayed Start and Amperometric Sensitivity; Gate Run Amperometric Sensitivity

CAME ZLJ24
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
X 3
X 2
X 4
X 2
X 5
X 2
X 6
X 2
Pag.
18
18 - Manual code:
319U98EN
319U98EN ver.
2
2 06/2013 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
% speed of deceleration: setting up the deceleration speed, expressed as a percentage between 10% and 50%.
Delayed start: After an open or close command, the gate leaves start at a slow speed for a few seconds.
Amperometric sensitivity: the level of gearmotor sensitivity in the face of obstacles during operation.
When the amperometric sensitivity is on, and an obstacle is engaged, depending on how the configuration, the gearmotor works
in the following ways:
- timed endpoint: it stops while performing a gate run;
- end point: it inverts direction of travel during operation;
- decelerations: it inverts direction of travel during operation, while during the deceleration phase it stops;
- Fcap-RallCh.: it inverts direction of travel during operation, while during the deceleration phase it only stops when on a closing run.
When the amperometric sensitivity is off, and an obstacle is engaged, the gearmotor stops when the maximum current threshold
is exceeded (i.e. overload).
N.B.: this function appears only if the “encoder” function is not selected in the FUNCTIONS menu.
Gate run amperometrics: setting the gearmotor sensitivity in the presence of obstacles.
N.B.: this function only appears if the amperometric sensitivity is selected (not with encoder configuration)
Less
sensitive
More
sensitive
< LANGUAGE
>
E
nglis
h
FUN
C
TI
O
N
S
TIMING ADJ
.
USER
S
Imp. Run
< LANGUAGE
>
En
g
lis
h
F
U
N
C
TI
O
N
S
TIMIN
G
AD
J
.
U
S
ER
S
Imp. Run
< LAN
GU
A
G
E
>
E
n
g
lis
h
F
UNCTION
S
T
IMIN
G
AD
J.
U
S
ER
S
Imp. Run
< LAN
GU
A
G
E
>
E
nglis
h
F
UNCTION
S
T
IMING ADJ
.
USER
S
Imp. Run
< low Down Spd >
20
low Down Spd
< 20
>
low Down Spd
< 21
>
< Slow Star >
Disabled
Partenza Rall.
< Disabled
>
Partenza Rall.
< Turn on
>
< Sens. Amperom >
Disabled
Sens. Amperom
< Disabled
>
Sens. Amperom
< Turn on
>
<Run Amperom>
-oooooooooooo+
Run Amperom
<
-oooooooooooo+
>
Run Amperom
<
-oooooooooooo+
>