Campbell CR1000X - 8.7.2 Sending an Operating System to a Remote Datalogger

Campbell CR1000X
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
l
PC200W and PC400 users, select the datalogger from the list and click Connect .
4. Select File Control at the top of the Connect window.
5. Click Send at the top of the File Control window.
6. Navigate to the C:\Campbellsci\Lib\OperatingSystems folder.
7. Ensure Datalogger Operating System Files (*.obj) is selected in the files of type list, select
the new OS .obj file, and click Open to update the OS on the datalogger.
Note the following precautions when sending as a program:
l Any peripherals being powered through the SW12 terminals will be turned off until the
program logic turns them on again.
l Operating systems are very large files. Be cautious of data charges. Sending over a direct
serial or USB connection is recommended, when possible.
8. Maintaining your datalogger 111