10. Specifications
Electrical specifications are valid over a -40 to +70 °C, non-condensing environment, unless
otherwise specified. Extended electrical specifications (noted as XT in specifications) are valid
over a -55 to +85 °C non-condensing environment. Recalibration is recommended every three
years. Critical specifications and system configuration should be confirmed with Campbell
Scientific before purchase.
162
163
163
164
166
169
171
173
10.1 System specifications
10.2 Physical specifications
10.3 Power requirements
10.4 Power output specifications
10.5 Analogue measurements specifications
10.6 Pulse measurement specifications 10.7
Digital input/output specifications 10.8
Communications specifications 10.9
Standards compliance specifications
174
Specifications
10.1 System specifications
Processor: Renesas RX63N (32-bit with hardware FPU, running at 100 MHz)
Memory (see Data memory (p. 38) for more information):
l 128 MB of flash + 4 MB battery-backed SRAM
l Data Storage: 4 MB SRAM + 72 MB flash
l Data Storage Expansion: Removable microSD flash memory, up to 16 GB
Program Execution: 1 ms to 1 day
Real-Time Clock:
l Battery backed while external power is disconnected
l Resolution: 1 ms
l Accuracy: ±3 min. per year, optional GPS correction to ±10 µs
10. Specifications 162