8200-M035-O1 Rev C ļ 200 Installation & Technical
SETUP AND CALIBRATION, CONT.
trA= (Zero Tracking Range)
Press the TARE/ENTER key to show the current value assigned to the Automatic Zero
Tracking Range. This is the value in scale divisions that will be automatically zeroed off. If the
setting displayed is acceptable, press the TARE/ENTER` key again to save it. Otherwise, use
the ASTERISK/UP ARROW key to toggle to a new setting and then press the TARE/ENTER
key to save it. Allowable values are: 0 (disables Zero Tracking), .5, or 1 through 9.
trL= (4% Zero Range)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the ASTERISK/UP ARROW
key to toggle to a new setting and then press the TARE/ENTER key to save it.
PUO= (Power-Up Zero Feature)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the ASTERISK/UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it.
Automatic Re-Zero on Power-Up
SLEEP= (Sleep Mode Feature)
The Sleep Mode feature conserves battery power when the indicator remains unused for a
selected period of time. With the feature enabled, the load cell excitation will be reduced and
the display will be blank.
Press the TARE/ENTER key to show the current status of this feature. If a number other than 0
is shown, this feature is selected and the number shown corresponds to the number of minutes
of a stable zero weight reading before the indicator enters the sleep mode.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the ASTERISK/UP ARROW key to toggle to a new setting and then press the TARE/ENTER
key to store the new setting. Allowable values are: 0 through 10. Note that selecting 0
disables this feature.
A oFF= (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off (when it is not in use)
after a predetermined period of inactivity to prolong battery life. To turn the indicator back on
you must press the ON / OFF key.
Press the TARE/ENTER key to show the current status for this feature. A number other than 0
indicates that the auto shutoff feature is enabled and the displayed number corresponds to the
number of minutes of stable weight displayed before the indicator is turned off automatically.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the ASTERISK/UP ARROW key to toggle to a new setting (0 to 10) and then press the
TARE/ENTER key to store the new setting. Allowable values are: 0 through 10. Note that
selecting 0 disables this feature.