8200-M035-O1 Rev C 200 Installation & Technical
SETUP AND CALIBRATION, CONT.
Print (Print?) – Print Tab Settings
With Print (Print?) displayed, press the TARE/ENTER key. The display will change to
show the current setting no. To skip configuring the Print Tab Settings and proceed to the
FSPAn? menu, press the TARE/ENTER key again. To configure the Print Tab Settings, press
the ASTERISK/UP ARROW key (display will change to YES) then the TARE/ENTER key. After
pressing the TARE/ENTER key the display will change to Port=.
The general format for the input is A = YY.XX where A is the
character identifying the data printed, YY is the number of lines
down and XX is the number of spaces to the right.
NOTE: Enter 00 in either the YY or XX location to
disable the data from printing.
Port= (Select Port for Printer)
Press the TARE/ENTER key to show the current value. If the
setting displayed is acceptable, press the TARE/ENTER key again
to save it. Otherwise, use the ASTERISK/UP ARROW key to toggle to a new setting and then
press the TARE/ENTER key to save it. Allowable values are: 1 or 2.
NOTE: Although either port can be used for the printer port, it is recommended to
use the bi-directional port 1 with a bi-directional cable.
id = (ID Prompt Print Location)
Press the TARE/ENTER key to show the current setting for the location of ID prompt printing.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the ASTERISK/UP ARROW and UNITS/LEFT ARROW keys to input a new location and
then press the TARE/ENTER key to save it.
CnC n= (Consecutive Number Print Location)
Press the TARE/ENTER key to show the current setting for the location of consecutive number
printing. If the setting displayed is acceptable, press the TARE/ENTER key again to save it.
Otherwise, use the ASTERISK/UP ARROW and UNITS/LEFT ARROW keys to input a new
location and then press the TARE/ENTER key to save it.
GroSS= (Gross Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Gross weight
printing. If the setting displayed is acceptable, press the TARE/ENTER key again to save it.
Otherwise, use the ASTERISK/UP ARROW and UNITS/LEFT ARROW keys to input a new
location and then press the TARE/ENTER key to save it.
tArE= (Tare Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Tare weight
printing. If the setting displayed is acceptable, press the TARE/ENTER key again to save it.
Otherwise, use the ASTERISK/UP ARROW and UNITS/LEFT ARROW keys to input a new
location and then press the TARE/ENTER key to save it.
nEt= (Net Weight Print Location)
Press the TARE/ENTER key to show the current setting for the location of Net weight printing.
If the setting displayed is acceptable, press the TARE/ENTER key again to save it. Otherwise,
use the ASTERISK/UP ARROW and UNITS/LEFT ARROW keys to input a new location and
then press the TARE/ENTER key to save it.