8200-M035-O1 Rev C 200 Installation & Technical
SETUP AND CALIBRATION, CONT.
Cont2= (Continuous Output Serial Port 2)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the arrow keys, select a new setting then
press the ENTER key to save it.
If Cont2= YES (Continuous Output) is selected, an additional prompt, tYPE= will be
displayed.
tyPE= (Continuous Output Format)
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER key again to save it. Otherwise, use the ASTERISK/UP ARROW key to
toggle to a new setting and then press the TARE/ENTER key to save it. Allowable values are:
8 = SB500 with Traffic Light
NOTE: See Continuous Output Serial Port 1, tYPE= for description of output formats.
tHrs= (Threshold Weight)
If any of the Serial Ports have been configured for continuous SB-500 with Traffic Light output,
this prompt will be displayed.
Press the TARE/ENTER key to show the current value. If the setting displayed is acceptable,
press the TARE/ENTER` key again to save it. Otherwise, use the ASTERISK/UP ARROW and
UNITS/LEFT ARROW keys to enter a new setting for the threshold weight and then press the
TARE/ENTER key to save it.
The threshold weight is used to automatically toggle between the Red and Green lights.
When the scale gross weight is less than the threshold weight, the Green light will be on,
otherwise the Red light will turn on and stay on until the weight goes below the threshold
weight or a ticket is printed.
When a ticket is printed, the Green light will turn on and stay on until the scale gross weight
goes below and back above the threshold weight and then the Red light will turn on.
NOTE: If you enter a zero (0) for the threshold weight (THRS=0), the traffic light feature
will be disabled (turned off).