lb-05046-03-EN Pag.48 22/01/2014
WARNING:
a) You can activate more than one actuator at the same time.
b) Once a time-out of 5 seconds has elapsed, the activated actuators will be automatically interrupted.
c) The “Milk pump speed” parameter will be displayed only for machine with milk pump installed.
Test actuators
- Actuators 1
- Actuators 2
- Actuators 3
- Milk pump
- Dispenser A
- Exhaust fan
- Electronic fan
Mixer A
Mixer A
Enter
Esc
Mixer test
A 0
Keep pressed the + key to
increase the speed of the
Mixer A motor . Keep
pressed the – Key to
decrase the speed.
0 -100 %
variable value
+ / -
Test actuators
- Actuators 1
- Actuators 2
- Actuators 3
- Milk pump
- Mixer A
- Exhaust fan
- Electronic fan
Dispenser A
Dispenser A
Enter
Esc
Dispenser test
A 0
0 -100 %
variable value
+ / -
Keep pressed the + key to
increase the speed of the
Dispenser A motor . Keep
pressed the – Key to
decrase the speed.
+
-
+
-
Exhaust fan test
OFF
Press + key to
switch on the fan.
Press – Key to
witch off the fan.
Esc
Test actuators
- Actuators 1
- Actuators 2
- Actuators 3
- Milk pump
- Mixer A
- Dispenser A
-Mixer B
- Dispenser B
- Electronic fan
Exhaust fan
Enter
+
-
Exhaust fan