Installation
1
2
When you install the gas pipe horizontally, make sure you form a 1/250 down
gradient (2cm down for a length of 5m) to facilitate refrigerant flows.
Insulate the liquid and gas pipes. If you combine the liquid and gas pipes for
insulation, then heat exchanges between them will degrade the compressor
performance significantly.
liquid pipe
insulation
wire
vinyll tape
gas pipe
insulation
Connecting the pipes between the indoor/outdoor unit
1
2
How to connect the pipe.
Use a flare connection method which is simple and quick.
As shown in the figure below, make a flare at the pipe end and fix the flare nut to
the valve for the indoor and outdoor unit.
Flare specification
A
D
Outer
diameter
A
Liquid 6.35 8.3~8.7
Gas
12.7 15.4~15.8
15.88 18.6~19
● Connect the extended drain hose
to the drain hose in the bottom of the unit.
(no leakage allowed.)