Carrier Standing Type Inverter Air Conditioner
● Before wiring, connect the pipes.
● First of all, do the ground connection.
● Use a power chord to supply power to the indoor unit.
● Before connecting the power, make wirings between the indoor and the outdoor units.
● According to the wiring diagram, firmly connect wires to the terminal.
Before connecting the power, place live L & neutral N and make a connection as shown in the picture.
● Use a power switch that has a minimum 3mm separation for all of the contact points.
● Indoor unit ground wire should be connected to the ground within the control box.
Wiring
Out/indoor unit wiring
- The entirety of the wiring is the responsibility of the installer.
WIRING
Indoor unit
Outdoor unit
LN3
123LN
Minimum connection wire size (mm
2
)
L N 3
1.5 1.5 1.5 1.5
brown blue black green/yellow
40
Caution