TABLE OF CONTENTS Continued
PARAGRAPH NUMBER Page
MESSAGECENTER 61...........................................................................
6.1 MESSAGECENTER MESSAGES 61.......................................................
ALARM TROUBLESHOOTING 71.................................................................
7.1 INTRODUCTION 71.....................................................................
7.2 NOTES 72..............................................................................
7.3 DRIVER / OPERATOR ALARMS 73..........................................................
1 LOW FUEL LEVEL WARNING 73.....................................................
2 LOW ENGINE OIL LEVEL WARNING 73...............................................
7.4 SHUTDOWN ALARMS 74..................................................................
11 LOW ENGINE OIL PRESSURE 74....................................................
12 HIGH COOLANT TEMPERATURE 75.................................................
13 HIGH DISCHARGE PRESSURE (ALARM 75 WILL ALSO ACTIVATE) 77..................
14 HIGH A/C AMPS 78.................................................................
15 BATTERY VOLTAGE TOO HIGH 79...................................................
16 BATTERY VOLTAGE TOO LOW 710...................................................
17 HIGH COMP DISCHARGE TEMP 711..................................................
18 LOW REFRIGERANT PRESSURE 712.................................................
19 LOW FUEL SHUTDOWN 714..........................................................
20 MAXIMUM COMPRESSOR ALARMS 715...............................................
21 TECHNICIAN RESET REQUIRED 715..................................................
22 LOW SUCTION SUPERHEAT 716.....................................................
23 A/C CURRENT OVER LIMIT 718.......................................................
27 HIGH SUCTION PRESSURE 720......................................................
28 CHECK REFRIGERATION SYSTEM 721...............................................
7.5 START UP / ENGINE ALARMS 722...........................................................
30 FAILED TO RUN MINIMUM TIME 722..................................................
31 FAILED TO START - AUTO MODE 723.................................................
34 ENGINE FAILED TO STOP 725........................................................
35 CHECK STARTER CIRCUIT 726.......................................................
36 CHECK COOLANT TEMPERATURE 727...............................................
37 CHECK LOW SPEED RPM 728........................................................
38 CHECK HIGH SPEED RPM 729.......................................................
39 CHECK ENGINE RPM 731............................................................
40 CHECK GLOW PLUGS (This alarm applies to the Intake Air Heater) 733....................
41 ENGINE STALLED 734...............................................................
7.6 WARNING / STATUS ALARMS 736...........................................................
51 ALTERNATOR NOT CHARGING (This alarm applies to the Battery Charger) 736.............
53 BOX TEMP OUT OF RANGE 737......................................................
54 DEFROST NOT COMPLETE 739......................................................
55 CHECK DEFROST AIR SWITCH 740...................................................
57 CHECK REMOTE SWITCH 1 (REMS1) 741.............................................