EasyManua.ls Logo

CAS CI-2400BS - Gravity Compensation Function Details; Multi-interval (Dual Range) Settings; Hold vs. Unit Conversion Selection; Decimal Point Format Selection

CAS CI-2400BS
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
GRAVITY COMPENSATION & THE OTHERS SET MODE
This mode set gravity compensation, dual range hold/unit conversion & decimal
specification.
1. How to Enter
Turn on while pressing CAL switch on the back side.
Press LIGHT/PRINT key and it will be moved to this mode.
2. Keys Usage
key: Increase the first place value by 1.
key: Used to set the current value 10.
key: Used to be moved to the next menu.
ZERO/MODE key: Used to set the current value to zero.
3. Description
Gravity Compensation Function:
This function allows it to be calibrated in one location and then adjusted to match
the acceleration of gravity at another location where it will be used.
Multi-interval(Dual range):
EX 1) If you calibrated minimum division to 1kg and maximum capacity to
3000kg
0
1500kg - minimum division is 0.5kg.
1500 3000kg - minimum division is 1kg.
EX 2) If you calibrated minimum division to 2kg and maximum capacity to
5000kg
0
2500kg - minimum division is 1kg.
2500 5000kg - minimum division is 2kg.
EX 3) If you calibrated minimum division to 5kg and maximum capacity to
10000kg.
0 4000kg - minimum division is 2 kg.
4000 10000kg - minimum division is 5kg.
HOLD/UNIT conversion: Select whether HOLD or UNIT conversion.
Decimal point: Select whether ‘ . ’ or ‘ , ’

Related product manuals