EasyManua.ls Logo

CAS CI-502A - Page 35

CAS CI-502A
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
`
36
F11 (0) Set the Zero Range ±2% ~ ±100%
F12 (9) Set the Tare Range ±2% ~ ±100%
F13 (2) Set the Initial Zero Range (Init Zero) ±2% ~ ±100%
F14 (09)
Set the Excessive Weight Check Range
(Weight Unit)
Excessive weight is from maximum
weight value to +99 division unit above
the maximum weight value.
F15 (0)
Set-up for allowing key input in the front of
the indicator
All keys functional / only the specified
keys functional
F16 (5) Set the purpose for Function key 1 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F17 (6) Set the purpose for Function key 2 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F18 (1) Set the purpose for key 4 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
F19 (1) Set the purpose for key 5 (0 ~ 29)
Use it in 22 code types
*(Function Code Table)
Communication & Print Function
F20 (01) Set the Device ID (00~99) Device ID
F21 (0) Set the parity bit (0 ~ 2) Data bit, stop bit, parity bit
F22 (0) Set the communication data (0 ~ 2)
Transmissions of indicated value / gross
weight / net weight
F23 (4) Set the RS-232C Baud Rate (0 ~ 8) 600bps ~ 115,200 bps
F24 (0)
Set the RS-232C-output format
(0 ~ 2)
22 bytes / 10 bytes / 18 bytes
F25 (0) Set the RS-232C output mode (0 ~ 7) Set 8 types of output modes
F26 (4) Set the PRINT Baud Rate 600bps ~ 115,200 bps
F27
(3)
Set the PRT- output mode Set 4 types of output modes
F31 (3) Set the output data and/or print format
Set 3 types of output data and/or 6 types
of print format
F32 (0) Automatic Print Set-up (0 ~ 2)
Manual print / Automatic print / Print in
series
F33 (0)
Initialization of Number Measured
Daily (0 ~ 1)
Maintain current number / Initialize data
after print-out
F34 (1) User Output Message (0 ~ 1) Do not use / Use
F35 (1) Set the Line Feed for Print
From no line feed to adjustment in lines
after printing out 1~9 lines
F36 (00) Set the Print Delay Time (00 ~ 99)
00: No delay in printing
99: Print after a 9.9 sec delay
F37 (0)
In Sub-total Print, Print Maximum,
Minimum and Average Values (0~1)
Print weight value / Print maximum,
minimum, and average values
F38 (0) Select the Print Characters
CP-7100/7200, DEP-50
DLP-50
F39 (0) Set the Print Output Range
0: All Weights (+),(-) possible for print-out
1: Weight must be (+) for print-out

Related product manuals