2
CAL 1
MAXIMUM CAPACITY SETTING
Available Setting Range : 1kg ~ 999,999kg
KEY FUNCTION DISPLAY DESCRIPTION
CAL 1
CAL 1 Condition
Increase or decrease
set value
5000
5000kg
Move one digit to left
10000
10000kg
ENTER Next Menu Save the value and go to CAL 2
Note 1. The maximum capacity means the maximum weight that the scale can measure.
CAL 2
MINIMUM DIVISION SETTING
Available Setting Range : 0.001kg ~ 100kg
KEY FUNCTION DISPLAY DESCRIPTION
CAL 2
CAL 2 Condition
1
1kg
Increase or decrease
set value
0.01
0.01kg
ENTER Next Menu
Save the value and go to CAL 3
Note 1. The minimum division means one division
Note 2. External resolution should be within 1/20,000.
(External resolution= a division/maximum weight).