Loading...
— 37 —
[ 10 ] CG READ test
[Function]
Perform the READ ONLY test for OG.
[Operation]
Operation : n 0 1 7 SUBTOTAL
n : 0 = One time check (can be omitted)
not 0 = Continuous check (Press “C” key or turn off the power by rotating the key to stop
this test.)
[PRINT]
The address is not printed when the error occurs.
CG 1 7
CG RD OK
END 17
NG is printed if CHECK SUM value is not normal.
[ 11 ] FLASH USER AREA clear test
[Function]
Clear the area of LOCALE/CONTRAST setting.
[Operation]
Operation : 2 1 2 SUBTOTAL
[PRINT]
NG is printed if the test is not done correctly.
ROM 2 1 2
ROM CLR OK
END 21 2

Table of Contents

Other manuals for Casio TE-2400