Cavli Wireless C100QM/C10QM Hardware Manual
85
work
Test duration: 30
Cycles;1 h+1h /cycle
normal
Alternating
hot and
humid
High temperature: 55oC
Low temperature: 25oC
Humidity: 95% ± 3%
Working mode: normal
work
Test duration: 6
Cycles;12 h+12
h/cycle
JESD22-A101-
B
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Temperatur
e shock
High temperature: 85oC
Low temperature: 40oC
Temperature change
time: < 30s
Working mode: no
packaging, no
Power on, do not boot
Test duration: 100
Cycles;15 min+15
Min/cycle
JESD22-A106-
B
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Drop test
Height 0.8 m, 6 sides each
time, dropped to the
horizontal marble
platform
Working mode: no
packaging, no
IEC60068-2-32
Visual inspection: normal
Function check: normal
RF indicator check:
normal

Table of Contents