User’s manual 47
EN
(g.38b); normally this unit is pre-calibrated to a pressure of 10Bar, with SAE20 viscosity
lubricant in order to make a drop of lubricant come out, which can be seen from the
specic cover, every 4 times the bead breaker is operated.
Periodically check the lubricant level through the specic windows and top up as shown
in g.38c. Top up only with non-detergent SAE20 oil equal to 50cc.
The lter regulator “FR” has an automatic condensation drain system, therefore in condi-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (g.38d). Normally the cups do not need to be removed,
but check if this is necessary for maintenance operations after a long period of use. If a
manual operation is not sufcient, use the specic key provided (g.38e).
Clean with a dry cloth. Avoid contact with solvents.
NOTE: for oil warnings, refer to the specic chapter in the machine user manual.
38