(g.38b); normally this unit is pre-calibrated to a pressure of 10Bar, with SAE20 viscosity
lubricant in order to make a drop of lubricant come out, which can be seen from the
specic cover, every 4 times the bead breaker is operated.
Periodically check the lubricant level through the specic windows and top up as shown
in g.38c. Top up only with non-detergent SAE20 oil equal to 50cc.
The lter regulator “FR” has an automatic condensation drain system, therefore in condi-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (g.38d). Normally the cups do not need to be removed,
but check if this is necessary for maintenance operations after a long period of use. If a
manual operation is not sufcient, use the specic key provided (g.38e).
Clean with a dry cloth. Avoid contact with solvents.
NOTE: for oil warnings, refer to the specic chapter in the machine user manual.