Assembly and operating instructions
CENTAX-L
016L-00050…00090-FS10
CENTA Antriebe Kirschey GmbH 29 / 46
Mount the link flange assembly (1) with/without sheet (5) as appropriate for
the supplied design, see installation drawing:
Mount with sheet (5):
Push the sheet (5) into the centring of the flywheel (B).
Push the link flange assembly (1) into the centring of the flywheel (B).
Screw the link flange assembly (1) and the sheet (5) to the flywheel (B)
using the screws (30) and the washers (31).
Mount without sheet (5):
Push the link flange assembly (1) into the centring of the flywheel (B).
Screw the link flange assembly (1) to the flywheel (B) using the screws
(30) and the washers (31).
Tightening torques for elements to connect couplings with customer parts could deviate
from CENTA data sheet D013-013.
Consider specifications on installation drawing.