IMPORTANT
We recommend the following mounting fluids:
For mounting:
Oil with a viscosity 300 mm
2
/s at 20°C, e.g. SKF LHMF300
For dismantling:
Oil with a viscosity 900 mm
2
/s at 20°C, e.g. SKF LHDF900
Remove the screw plug (19) from the hub (3).
Connect the pump (p
max
= 3000 bar) to the thread G¼ or G¾ (c) of hub (3)
to expand the hub.
Screw the pump to the shaft (A), in order to hold the hub.
Build up oil pressure in order to hold the hub.
WARNING
Material damage can occur as a result of:
Too fast increase of the expanding pressure in the hub
The increase of the expanding pressure may not exceed
35 bar/minute.
Slowly build up oil pressure to expand the hub (p
max
= 1500 bar).
Slowly reduce the oil pressure for holding the hub.
Slowly reduce the oil pressure for expanding the hub.
Repeat the above mounting section until the hub is completely released from
the shaft.
Remove the pump for holding the hub from the shaft (A).
Remove pump for expanding the hub from the hub (3).
Turn the hub (3), drain oil out of the thread G¼ or G¾ (c) and dispose
correctly.
Screw the screw plug (19) into the hub (6).
Remove the hub (3) from the shaft (A).
9.5 Reassembling the coupling
Reassemble the coupling as described in chapter 6.