EasyManua.ls Logo

Centa CENTAX-L - Dismantling the Hub (if Necessary); Dismantling the Hub with Cylindrical Bore and Keyway; Dismantling the Hub with Conical Oil Interference Fit

Centa CENTAX-L
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembly and operating instructions
CENTAX-L
016L-00050…00090-FS10
M016-00003-EN
Rev. 3
CENTA Antriebe Kirschey GmbH 42 / 46
9.4 Dismantling the hub (if necessary)
Dismantle the hub (3) as appropriate for the supplied design (see installation
drawing):
Dismantling the hub with cylindrical bore and keyway,
see chapter 9.4.1 .
Dismantling the hub with conical oil interference fit,
see chapter 9.4.2 .
9.4.1 Dismantling the hub with cylindrical bore and keyway
See Fig. 6-3:
Remove the hub (3) from the shaft (A).
9.4.2 Dismantling the hub with conical oil interference fit
See Fig. 6-4:
WARNING
Injury and material damage can occur as a result of:
Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.
WARNING
Injury and material damage can occur as a result of:
Hydraulic fluid spraying out
Use protective goggles.
WARNING
Injuries and material damages can occur by:
Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.