Assembly and operating instructions
CENTAX-L
016L-00050…00090-FS10
CENTA Antriebe Kirschey GmbH 42 / 46
9.4 Dismantling the hub (if necessary)
Dismantle the hub (3) as appropriate for the supplied design (see installation
drawing):
Dismantling the hub with cylindrical bore and keyway,
see chapter 9.4.1 .
Dismantling the hub with conical oil interference fit,
see chapter 9.4.2 .
9.4.1 Dismantling the hub with cylindrical bore and keyway
See Fig. 6-3:
Remove the hub (3) from the shaft (A).
9.4.2 Dismantling the hub with conical oil interference fit
See Fig. 6-4:
Injury and material damage can occur as a result of:
Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.
Injury and material damage can occur as a result of:
Hydraulic fluid spraying out
Use protective goggles.
Injuries and material damages can occur by:
Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.