chapter 5000
page 81
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
STEER TABLE (MASTER connection number 3)
Press ROLL and PARAM together
Press ROLL
Press ENTER
Select the type of truck according to the 3 wheels or 4 wheels configuration.
OPTION #1 3 WHEELS 1,2-2,0 t AC
OPTION #2 4 WHEELS 1,2-2,0 t AC
OPTION #3 cenTAURO 160-200 L AC/C4E 160-200 NL AC
Scroll the parameters using ROLL
* CONFIG. MENU *
SET MODEL
* CONFIG. MENU *
SET OPTIONS
DA2M2B C CE 1.13
48V 280A 00000
HOUR COUNTER RUNNING/ KEY ON
BATTERY CHECK ON/OFF
HYDRO KEY ON ON/OFF
STOP ON RAMP ON/OFF
AUX INPUT #1 EXCLUSIVE HYDRO
OPTION #1
CUT BACK SPEED
PEDAL BRAKING ANALOG/DIGITAL
SET TEMPERATURE ANALOG/DIGITAL/NONE
STEER TABLE OPTION #1
OPTION #2
OPTION #3
Select OPTION #1 for the 3 wheels and store the parameter pressing OUT and then ENTER to
confirm.
Select OPTION #2 for the 4 wheels and store the parameter pressing OUT and then ENTER to
confirm.
Select OPTION #3 for the cenTAURO 160-200 L AC/C4E 160-200 NL AC and store the parameter
pressing OUT and then ENTER to confirm.