chapter 5000
page 82
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
STOP ON RAMP (MASTER connection number 3)
Press ROLL and PARAM together
Press ROLL
HOUR COUNTER RUNNING/ KEY ON
BATTERY CHECK ON/OFF
HYDRO KEY ON ON/OFF
STOP ON RAMP ON/OFF
AUX INPUT #1 EXCLUSIVE HYDRO
OPTION #1
CUT BACK SPEED
PEDAL BRAKING ANALOG/DIGITAL
SET TEMPERATURE ANALOG/DIGITAL/NONE
STEER TABLE OPTION #1
OPTION #2
Select STOP ON RAMP and change the status using PARAM or SET
ON ACTIVATED
OFF DEACTIVATED
and store the parameter pressing OUT and then ENTER to confirm.
After releasing the pedals the truck can stay still on a ramp for about 1 second.
This parameter activates/deactivates this function.
Press ENTER
Scroll the parameters using ROLL
* CONFIG. MENU *
SET MODEL
* CONFIG. MENU *
SET OPTIONS
DA2M2B C CE 1.13
48V 280A 00000