2. Now you can authorise any number of master media one after the other by holding each
master media for ca 1 second in the reading field of the locking device.
The following signal appears for each master media:
1x short green
3. Hold the System-Master for ca 1 second in the reading field of the locking device to end the
“authorise mode.
The following signal appears:
1x long green
The authorise mode will end automatically after 5 seconds. Die new authorisations
remain stored.
All master media, which were held before reading field, are now authorised to make settings for
this locking device.
Troubleshooting:
Signalling Reason Solution
During step 2:
The master media could be read but
could not be authorised:
a) You have tried to authorise a
Program-Master for a V-NET locking
device.
a) Program-Master cannot be authorised
for V-NET devices.
b) The master media has the wrong
system identity code
b) Use a master media with the correct
system identification code.
c) You have used a locking media
instead of a master-media.
c) Use a master media.
d) you have tried to authorise an RF-
Trace-Master or an RF-Ini-Master.
d) RF-Trace-Master and RF-Ini-Master
cannot be authorised.
Page 112 of 141 Long shield ILS
11.2 Authorising additional master media
Overview: Master media usage