9 Technical data
9.1 Features
Part numbers ILS / x
Suitable locking media
LEGIC All locking media of the type LEGIC prime and LEGIC advant, all locking media to ISO
14443
MIFARE® MIFARE® Classi (1k/4k), MIFARE® DESFire® EV1 and EV2 (UID to ISO 14443 and
application), all locking media ISO 14443 (except MIFARE Ultralight® C)
Reading range Approx. 20 mm
Online radio frequency 868 MHz
RF range to Access-Point Max. 25 m
Encrypted data transmission 128 bit/AES
Variants Narrow shield for use on narrow stile doors, wide shield for use on flush doors,
combinations of the two types. Narrow shield to DIN EN 1125, wide shield to DIN EN 1125
The design of the shields enables prep-free installation on replacement of most fittings
prepared to DIN/EN standards.
Power supply Battery: 2 x Energizer Ultimate Lithium 1,5V AA
Number of locking media Max. 5.000
Number of events Max. 2.000
Number of Master media Max. 1 System-Master, max. 10 Program-Master, max. 10 Time-Master, max. 10 Release-
Master, max. 10 Block-Master, max. 10 RF-Stick-Master, max. 100 Emergency-Keys, RF-Ini-
Master unlimited, RF-Trace-Master unlimited
Outdoor shield temperature 25 °C to +70 °C for the electronics, in weatherproof standard
Indoor shield temperature 25 °C to +70 °C
Prohibited atmospheres Not suitable for use in corrosive atmospheres
(chlorine, ammonia, lime water)
Service life of the ILS Conforming to DIN EN 1906, Grade 7, 200.000 cycles
Service life of the battery Approx. 100.000 locking cycles at 20 °C
Programming With Master media, Offline via radio with RF-Stick, CEStronics RF-NET radio network,
CEStronics V-NET virtual network
Uses Conforming to DIN EN 179 and DIN EN 1125 with different locks and panic bars
Fire resistance rating 120 minutes conforming to DIN EN 1634-1 and 18273 (T120)
Special designs Burglar resistance, various lever handle designs, various thumb turns, mechanical ILS
without electronics
Door thicknesses From 35 mm to 165 mm
Backsets From 25 mm
Distances From 55 to 100
Handle square hole 9 mm
Available spindles 7 mm, 8 mm, 8,5 mm, 9 mm und 10 mm
Cylinder profile apertures Without (00), Euro (PZ), CH (RZ), UK (OZ)
Safety classes Optionally conformity to DIN EN 18257 ES2 or to NEN SKG***,
DIN EN 1906 Grade 3
CE testing EN 300 220-1-2; EN 300 330-1-2; EN 301 489-1, 3; EN 60950-1, EN 62311
Ordering information
Required cylinder lenght 22,5 mm + door thickness + 22,5 mm