2. Now you can delete any number of locking media one after the other by holding each
locking media for ca 2 second in front of the reading field of the locking device.
The following signal appears for each locking media:
2x short green
3. Hold the Program-Master for ca 1 second in the reading field of the locking device to end
the “delete locking media” mode
The following signal appears:
1x long green
The delete locking media mode will end automatically after 5 seconds. The locking media
which were previously held before the locking device will thereby be deleted from the
locking device.
All locking media, which were held in the reading field, are now no more authorised to open this
locking device.
Troubleshooting:
Signalling Reason Solution
During step 1:
The program-Master was not yet author-
ised for this locking device.
Authorise the Program-Master.
During step 2:
The locking media was not authorised
with the Program-Master used
Use Program-Master with which the lock-
ing media was authorised
The locking media was held for too short
a period in the reading field of the locking
device. The authorisation was not deleted.
Hold the locking media longer in the read-
ing field of the locking device.